Every module, every fault on one map
Radiometric thermography to IEC TS 62446-3: hotspots, defective bypass diodes, substrings and shading detected per module, georeferenced and documented for warranty claims.
Yield is lost quietly.
A defective module lowers the yield of an entire string without the inverter raising an alarm. From the air we inspect the entire module area in one flight, at an irradiance of at least 600 W/m², and assign every finding to a module. Your maintenance team gets a map, not a suspicion.
What you receive
Fault report per module
Classified to IEC TS 62446-3: hotspot, bypass diode, substring, cell crack, shading, soiling.
Georeferenced fault map
Every finding with its position in the site plan, directly accessible for repair.
RGB detail images
48 MP per module: glass breakage, delamination, snail trails, substructure.
Proof after maintenance
Verification flight with an identical flight plan: fixed faults documented, open ones visible.
From briefing to report
Installation data
Module type, string plan, yield data and access. We plan the flight around the irradiance.
Flight
Grid flight under clear skies and high irradiance, thermography and RGB in a single pass.
Analysis
Findings classified per module and matched against the string data.
Report
Fault report and map within 48 hours, recommendations included.
The technology behind it
Industries that benefit
For operators, property managers and owners with modules on the roof or in the field.

Solar & PV Operators
Yield losses made visible: radiometric inspection to IEC TS 62446-3, a fault report per module, white-label on request.

Building Management
Every roof and façade documented: no scaffolding costs, no disturbed residents, with a prioritised report in 48 hours.

Hotels & Resorts
Inspection and thermography without interrupting operations: flown before breakfast service, invisible to your guests.

Insurance Brokers & Loss Adjusters
Damage imagery with timestamp and geodata: traceable evidence for storm, hail and water damage, without scaffolding or height access.

Developers & Construction Companies
From first excavation to handover: evidence volumes, document progress, inspect the building envelope before acceptance.

Golf Clubs
Irrigation diagnosed from the air: leaks and drought stress found before the turf turns brown. Without closing a single flight.
Packages by industry
From the single check to the audit and ongoing monitoring of your sites.
Frequently asked questions
Clear skies, an irradiance of at least 600 W/m², little wind and dry modules. On the Costa del Sol these conditions are met on most days of the year.
Yes. The report follows IEC TS 62446-3 and documents every finding radiometrically and georeferenced. That is the basis manufacturers and installers work with.
Once a year as standard, every six months for larger installations or after storms. In the Aerial PV Monitor package we set the cadence together.
Your installation, inspected module by module.
Describe your property and your question. You receive a tailored proposal within two working days.
Confidential, without obligation, answered within two working days.